Teledyne Instruments - Tekmar
Have questions? Need help?
513.229.7000 | 800.874.2004
Have questions? Need help?  Give us a call.

Company Information
About Us
Location
 
News and Events
News Room
Seminars
Training Courses
Trade Shows
Career Opportunities
 
Help Center
Software Downloads
ISO 9001:2000
Privacy Policy
Terms of Use
P. O. Terms & Conditions
Terms & Conditions of Sale
Site Map
 
Print this page Print this page
Email this page Email this page
   

Products
Products: Apollo 9000 Total Organic Carbon (TOC) Analyzer™
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Section Links: TOC Products l VOC Products

Apollo 9000 Total Organic Carbon (TOC) Analyzer Accessories

TOC Certified Reference Standards
Teledyne Tekmar, in conjunction with Pharmaceutical Resource Associates (PRA), now proudly offers a full suite of certified TOC reference standards for all TOC instrument manufacturers. Click here for more information on our TOC Certified Reference Standards.

ATLAS Valveless Sample Handling System
Many applications require Total Organic Carbon (TOC) analysis of highly particulated samples or difficult matrices like brine. On traditional analyzers that employ valves in the sample pathway, these applications require either additional maintenance or cannot be run without significant pre-treatment. The ATLAS sample handling system employs an injection port design solution for valveless TOC analysis, making difficult matrices a common sample.

STS 8000 AutosamplerReliable, High Throughput STS 8000 Autosampler
The STS 8000 Autosampler is a high capacity, dependable robotic XYZ autosampler suitable for virtually any TOC sample. With easy access to sample racks, sample loading is fast and easy.Sample cross-contamination concerns are eliminated with a built-in needle rinsing function. The STS 8000 supports a variety of industry standard glassware (many with cap and septa), giving you the lowest possible cost of operation. A magnetic stirrer option is available for meeting ISO 8245 and EN-1484 requirements. The STS-8000 also provides the user with an option of acid addition and sparging in the sample vial for IC removal that allows for faster
sample analysis.

Total Nitrogen (TN ) Module
Many applications require both TOC and TN analysis. To meet this need for our customers, Teledyne Tekmar can provide an optional TN module with our Apollo line of TOC instruments. This compact module will measure TN simultaneously with TOC using a chemiluminescence detector and in accordance with your water requirements such as EN-12260 and DIN-EN-ISO 11905-2.

183 Boat Sampler
The Teledyne Tekmar 183 Boat Sampler is an ideal add-on to Teledyne Tekmar’s line of Total Organic Carbon (TOC) analyzers. Integrated with the Apollo 9000 Total Organic Carbon (TOC) or Phoenix 8000 Total Organic Carbon (TOC) analyzers, the 183 TOC Boat Sampler uses a high-temperature oxidation method for rapid analyses of:

• Soils
• Sediments
• Sludges
• Particulate-laden liquids
• Hard-to-oxidize samples

The flip-top hatch inlet, manual boat advance and high temperature combustion tube provide for simple and reliable operation. Designed for the laboratory, the Boat Sampler is light, compact and requires a minimum of bench space. The optional Carbon Range Extension Kit increases the upper range capacity of the boat sampler to 8% of carbon based on a 10 mg sample. This added feature allows the user to measure larger quantities of solids and sludge samples without incurring over-range
problems.

Total Carbon (TC) is measured by direct injection of sample without pretreatment. TOC is measured by sparging off the Inorganic Carbon (IC) from the acidified sample before injection, using the sparging station built into the instrument. IC is measured by injecting the water sample into a special vessel containing acidified water; the CO2 produced is swept to the analyzer’s detector module and measured.

Syringeable samples are injected directly into the platinum sample boat. Non syringeable samples, such as slurries and particle-laden liquids, are injected
through the same removable septum port using a positive-displacement micropipette. Solid samples are weighed into the removable boat, which is readily
accessible through the hatch-covered port. The boat is manually advanced into the furnace, where the sample is combusted at 800°C* in a stream of oxygen.

* Furnace temperature is adjustable up to 1000°C.

--------------------------------------------------------------------------------------------------------------------------------------------------------------
Click here to download 183 Boat Sampler Fact Sheet
--------------------------------------------------------------------------------------------------------------------------------------------------------------
Related Industries: Waste Water, Industrial Waste Effluent, Drinking and Surface Water, Ground Water, Clean-in-Place (CIP) Validation, Sea Water, Brine Solutions
Methods: EPA 415.1, 415.3 and 9060A, Standard Method 5310B, EP 2.2.44, ISO 8245,EN 1484, USP 643 (Chapter 24), ASTM D2579, prENV 13370, AOAC 973.47
Keywords: Dohrmann, Apollo 9000 Total Organic Carbon (TOC) Analyzer, STS 8000 Autosampler, Particulate Analysis, Combustion TOC/TN Analyzer
--------------------------------------------------------------------------------------------------------------------------------------------------------------
Dohrmann Series
Apollo Quick Links
| Apollo Home
| Application Notes
| Accessories
| TOC Reference Standards
| Flow Diagrams
| Software
| Specs
| Product Literature
| Troubleshooting
------------------------------------------------------------------------
More Information
| Contact Sales
| Attend Apollo Training Course
| Attend Apollo Seminar
| Attend a Trade Show
 
   
TOC Products: Apollo 9000Fusion TOC AnalyzerPhoenix 8000   
VOC Products: AQUATek 70 | AUTOCan 12 | HT3 | SOLATek 72 | Stratum PTC | Velocity XPT

ISO 9001:2000 | Privacy | Terms of Use | Site Map

Teledyne Tekmar | 4736 Socialville Foster Road | Mason, Ohio 45040
[p] 800.874.2004 | tekmarinfo@teledynetekmar.com | [f] 513.229.7050

Copyright © 2010 Teledyne Technologies Incorporated. All rights reserved.