Teledyne Instruments - Tekmar
Have questions? Need help?
513.229.7000 | 800.874.2004
Have questions? Need help?  Give us a call.

Company Information
About Us
Location
 
News and Events
News Room
Seminars
Training Courses
Trade Shows
Career Opportunities
 
Help Center
Software Downloads
ISO 9001:2000
Privacy Policy
Terms of Use
P. O. Terms & Conditions
Terms & Conditions of Sale
Site Map
 
Print this page Print this page
Email this page Email this page
Applications
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Section Links: Application Notes l Method Development l Product Specialists
 

Simplifying the Process: Automated USP 643 / EP 2.2.44 Purified Water and Water For Injection Testing Using A Next Generation Total Organic Carbon (TOC) Analyzer
Industry:
Pharmaceutical
Instrument: Fusion Total Organic Carbon (TOC) Analyzer

The United States Pharmacopoeia (USP) <643> and European Pharmacopoeia (EP) 2.2.44 monographs provide guidelines and requirements for Total Organic Carbon (TOC) analysis of water for injection and purified water.   These methods present a system suitability test that compares the recovery of a standard solution (rs) of sucrose, a relatively easy compound to oxidize, and the system suitability solution (rss) of 1,4-benzoquinone, the challenge compound. The response of reagent water (rw) is subtracted from each of these solutions’ responses to yield a corrected response.  The maximum carbon concentration of the reagent water per these monographs is 100 ppb C.  However, when reagent water concentrations are below 50 ppb C, greater accuracy may be obtained through lower instrument / reagent blank values.  From the results, a response efficiency (E) is calculated by dividing the corrected system suitability solution response by the corrected standard solution response and multiplying by 100. According to both pharmacopoeias, the response efficiency must achieve between 85% - 115% for the instrument to be suitable for total organic carbon (TOC) analysis on pharmaceutical pure water (PW) and water for injection (WFI) samples.

Application Note Click here to download this Application Note.*
   
* Requires registration

ISO 9001:2000 | Privacy | Terms of Use | Site Map

Teledyne Tekmar | 4736 Socialville Foster Road | Mason, Ohio 45040
[p] 800.874.2004 | Tekmarinfo@teledyne.com | [f] 513.229.7050

Copyright © 2010 Teledyne Technologies Incorporated. All rights reserved.